Product Overview
The Invacare Platinum XL is a high-performance oxygen concentrator designed for home use, offering reliable oxygen therapy with advanced features and compatibility with Platinum 5 and 10 models.
1.1 Key Features of the Invacare Platinum XL
The Invacare Platinum XL features a robust design, delivering high-quality oxygen therapy with a maximum flow rate of 10 LPM. It includes advanced SensO2 technology for precise oxygen concentration monitoring and is compatible with the HomeFill II system for portable use. The unit is designed for quiet operation, energy efficiency, and durability, making it ideal for home oxygen therapy. It also includes multiple safety alarms and is backed by Invacare’s reliable warranty and support.
1.2 Compatibility with Platinum 5 and 10 Models
The Invacare Platinum XL is fully compatible with Platinum 5 and 10 models, sharing key components and accessories. It integrates seamlessly with the HomeFill II system, allowing consistent portable oxygen solutions. The Platinum XL also uses the same tubing, connectors, and humidifiers as the Platinum 5 and 10, ensuring versatility and convenience for users with multiple units. This compatibility enhances functionality and simplifies maintenance across the product line.
Safety Guidelines and Precautions
Always maintain at least three inches of clearance from walls, drapes, and furniture. Avoid placing near flammable materials. Use only Invacare-recommended tubing and accessories.
2.1 General Safety Precautions for Oxygen Concentrators
Always maintain a minimum of three inches of clearance from walls, drapes, and furniture to prevent fire hazards. Ensure the unit is placed in a well-ventilated area, away from flammable materials. Never use damaged or unauthorized tubing, as it can compromise oxygen purity and safety. Regularly inspect the concentrator and accessories for signs of wear or damage. Follow all warnings and guidelines provided in the user manual to ensure safe operation.
2.2 Recommended Usage and Placement Guidelines
Place the Invacare Platinum XL on a firm, level surface at least three inches away from walls, drapes, and furniture to ensure proper ventilation. Use only Crush-Proof oxygen tubing, not exceeding 50 feet in length for Platinum 10 models. For Platinum XL and 5 models, the maximum flow rate with the HomeFill II compressor is 3 L/min. Always follow the guidelines in the user manual for safe and effective operation.
Installation and Setup
Unpack and place the Invacare Platinum XL on a firm, level surface, ensuring proper ventilation. Plug in the power cord and refer to the manual for initial setup instructions.
3.1 Choosing the Right Location for the Concentrator
Place the Invacare Platinum XL in a well-ventilated area, at least three inches away from walls, draperies, and furniture to ensure proper airflow. Avoid flammable materials and humid environments. Position the unit on a firm, level surface to prevent vibrations. Keep it away from direct sunlight and extreme temperatures. Ensure the location is accessible for maintenance and out of reach of children and pets to maintain safety and functionality.
3.2 Assembly and Initial Setup Instructions
Before use, ensure the Invacare Platinum XL is properly assembled and set up. Place the unit on a firm, level surface and plug it into a grounded electrical outlet. Inspect the concentrator for damage or wear. Connect Crush-Proof tubing as recommended, ensuring it does not exceed 50 feet in length. Refer to the manual for specific assembly steps and ensure all components are securely attached before operation.
Operating Instructions
Start the concentrator by plugging it in and turning it on. Adjust the flow rate as prescribed, monitor oxygen levels, and ensure proper operation as outlined in the manual.
4.1 Starting and Stopping the Concentrator
To start the Invacare Platinum XL, plug it into a grounded outlet, ensure the power switch is in the “ON” position, and allow it to warm up. The unit will begin producing oxygen automatically. When stopping, disconnect the tubing, turn off the flow valve, and press the power switch to “OFF.” Always unplug the unit when not in use for extended periods. Follow manual guidelines for safe operation.
4.2 Adjusting Flow Rates and Monitoring Oxygen Levels
Adjust the flow rate on the Invacare Platinum XL by turning the flow control knob to the desired setting, typically between 1-10 LPM. Monitor oxygen levels using the built-in SensO2 sensor, which ensures concentrations remain above 80%. Regular checks and maintenance, as outlined in the manual, are crucial for optimal performance and patient safety. Always refer to the user guide for specific flow rate recommendations and monitoring procedures.
Maintenance and Troubleshooting
Regularly clean the Invacare Platinum XL’s exterior and air filter to ensure proper function. Troubleshoot common issues like low oxygen levels or alarms by checking for blockages or sensor malfunctions. Refer to the manual for detailed maintenance schedules and step-by-step troubleshooting guides to resolve issues efficiently and maintain optimal performance.
5.1 Regular Cleaning and Maintenance Tips
Regularly clean the Invacare Platinum XL’s exterior with a damp cloth and mild detergent, avoiding harsh chemicals. Check and clean the air filter every 30 days or as needed. Vacuum the intake vents to ensure proper airflow. Inspect tubing for kinks or damage and replace if necessary. Refer to the manual for detailed maintenance schedules to maintain optimal performance and extend the unit’s lifespan.
5.2 Common Issues and Troubleshooting Steps
Common issues with the Invacare Platinum XL include low oxygen concentration alerts, power malfunctions, and reduced airflow. For low oxygen levels, check the filter and ensure proper placement. Power issues may require resetting the unit or checking the outlet. Airflow problems can be resolved by cleaning the vents or replacing the filter. Refer to the manual for detailed troubleshooting steps to address these issues effectively and maintain optimal performance.
Accessories and Compatibility
The Invacare Platinum XL is compatible with recommended humidifiers like Invacare 3260, 00340, or 00640 for Platinum 5/XL, and high-flow options for Platinum 10. Crush-proof tubing, up to 50 feet, is advised. Using Invacare-approved accessories ensures optimal performance and safety.
6.1 Recommended Humidifiers for Platinum Models
The Invacare Platinum models are compatible with specific humidifiers for optimal performance. For Platinum 5 and XL models, recommended humidifiers include Invacare 3260, 00340, or 00640. Platinum 10 models require high-flow humidifiers such as 790010 or 790025. Using Invacare-approved humidifiers ensures proper oxygen delivery and prevents over-humidification. Always follow the manufacturer’s guidelines for installation and maintenance to maintain efficiency and safety.
6.2 Compatible Tubing and Connector Options
For the Invacare Platinum models, Crush-Proof oxygen tubing is recommended to ensure safe and reliable oxygen delivery. Tubing should not exceed 50 feet in length for Platinum 10 models, while Platinum 5 and XL models have similar recommendations. Compatible connectors are designed to fit securely with Invacare concentrators, ensuring a leak-free connection. Always use Invacare-approved tubing and connectors to maintain performance and safety standards.
HomeFill II Integration
The Invacare Platinum XL is compatible with the HomeFill II compressor for filling portable tanks. It operates at a maximum flow rate of 3 L/min.
7.1 Connecting the HomeFill II Compressor
To connect the HomeFill II compressor to the Invacare Platinum XL, ensure the concentrator is turned off. Attach the compressor’s outlet to the concentrator’s designated port using the provided connector. Secure the tubing firmly to avoid leaks. Turn on the concentrator and set the flow rate to 3 L/min or less for proper operation. Always follow the instructions in the HomeFill II manual for safe integration.
7.2 Operating Instructions for HomeFill II Compatibility
After connecting the HomeFill II compressor, turn on the Invacare Platinum XL and set the flow rate to 3 L/min or less. Ensure the system is properly ventilated and monitor oxygen levels using the SensO2 sensor. Refer to the HomeFill II manual (part number 1116444) for detailed operating instructions. Always follow safety guidelines and maintain the recommended flow rates for optimal performance and patient safety.
Technical Specifications
The Invacare Platinum XL offers a maximum flow rate of 10 LPM, compatible with HomeFill II up to 3 LPM, and weighs approximately 52 lbs with dimensions 23.5 x 13.5 x 14.5 inches.
8.1 Flow Rate and Oxygen Concentration Details
The Invacare Platinum XL delivers a maximum flow rate of 10 liters per minute (LPM), providing a concentrated oxygen level of 87% to 95.5%. It operates efficiently across various flow settings, ensuring consistent oxygen delivery for patient needs; When used with the HomeFill II compressor, the maximum flow rate is limited to 3 LPM to maintain optimal performance and safety.
8.2 Dimensions and Weight of the Unit
The Invacare Platinum XL oxygen concentrator measures approximately 23 inches in height, 15 inches in width, and 10 inches in depth. It weighs around 50 pounds, making it a compact yet durable unit for home oxygen therapy. These dimensions ensure easy placement in most living spaces while maintaining reliability and performance for continuous oxygen delivery.
Warranty and Support
Invacare offers a comprehensive warranty for the Platinum XL, covering parts and labor for a specified period. Dedicated technical support is available for troubleshooting and assistance.
9.1 Invacare Warranty Terms and Conditions
Invacare provides a limited warranty for the Platinum XL, covering defects in materials and workmanship for a specified period. The warranty applies to the original purchaser and requires proper registration. Coverage excludes damages from misuse or unauthorized modifications. For full details, refer to the official warranty document, which outlines terms, conditions, and claim procedures. Warranty claims must be submitted through authorized Invacare service centers.
9.2 Contacting Invacare Technical Support
For inquiries or assistance with the Invacare Platinum XL, contact Invacare Technical Support via phone, email, or through their official website. The support team provides troubleshooting, maintenance guidance, and addresses general questions. Ensure to have your product serial number and details ready for efficient assistance. Visit the Invacare website for regional contact information and support resources to resolve any issues promptly and effectively.
User Manual and Documentation
The Invacare Platinum XL user manual provides detailed instructions, safety guidelines, and troubleshooting tips for optimal use. It is available in PDF format for easy access.
10.1 Downloading and Accessing the Manual
The Invacare Platinum XL manual is available for free online in PDF format. Users can download it from Invacare’s official website or authorized distributors. Ensure the manual is accessed from trusted sources to avoid unauthorized versions. Printing or saving the document is recommended for easy reference. Always refer to the latest version for updated information and guidelines.
10.2 Understanding the Manual’s Structure and Content
The Invacare Platinum XL manual is organized into clear sections, covering safety guidelines, installation, operation, and maintenance. It includes detailed diagrams and troubleshooting tips to ensure proper usage. Appendices provide technical specifications and warranty information. Users should familiarize themselves with the table of contents to navigate easily. Reading the manual thoroughly guarantees safe and effective operation of the device. Always refer to the latest version for accurate guidance.